Type |
L1 |
H1 |
H2 |
W1 |
LSW05-50 SRW05-30 |
145 |
100 |
78 |
60 |
LSW80
|
230 |
110 |
85 |
60 |
LSW100
|
280 |
115 |
85 |
60 |
LSW & SRW SERIES LIMITLOAD
The LSW &SRW units can be wired in different configurations. Wired in series then either switch will provide the cut out. The units however could be wired into 2 independent circuits providing even higher security switching.
For LSW units normal series operation the Blue and White cables should be connected together and the load connected across Black and Yellow
For SRW units normal series operation the Blue and Green cables should be connected together and the load connected across Black and Red
These units comply with the requirements of BS EN12077-2 & BS EN13849-2
Electrical Connections
Black......Com 1 Blue......Com 2
Green.....N/O 1 Red.......N/O 2
White......N/C 1 Yellow...N/C 2
Contact Rating
6 Amps 125 - 400 Volts AC
0.5 Amps 250 Volts DC
load Type | Operation | Range (kN) | Range (kg) | Max Rope (mm) |
LSW05 | Overload | 1-6 | 102-612 | 14 |
LSW10 | Overload | 5-12.5 | 510-1,275 | 14 |
LSW20 | Overload | 10-22.5 | 1,019-2,294 | 16 |
LSW30 | Overload | 20-32.5 | 2,038-3,313 | 20 |
LSW50 | Overload | 30-50 | 3,058-5,097 | 24 |
LSW80 | Overload | 45-80 | 4,587-8,155 | 24 |
LSW100 | Overload | 80-100 | 8,155-10,190 | 24 |
SRW05 | Slack Rope | 0.25-2.5 | 25-255 | 14 |
SRW10 | Slack Rope | 1-5 | 102-510 | 14 |
SRW20 | Slack Rope | 2.5-7.5 | 255-764 | 16 |